| Parameter | Unit | DY-LSM-PET-01 | DY-LSM-PET-02 | DY-LSM-PET-03 | DY-LSM-PET-04 |
| Variant | Fine screening | Medium screening | Open drainage | Coarse drainage | |
| Material | Polyester monofilament or mixed-yarn fabric, as listed | Polyester monofilament or mixed-yarn fabric, as listed | Polyester monofilament or mixed-yarn fabric, as listed | Polyester monofilament or mixed-yarn fabric, as listed | |
| Warp filament | mm | 0.5 | 0.7 | 0.6 | 1 |
| Weft filament | mm | 0.5 | 0.7 | 0.6 | 1 |
| Warp density | threads/cm | 9.7 | 7 | 5.9 | 2.85 |
| Weft density | threads/cm | 10.3 | 7 | 5.6 | 2.65 |
| Fabric mass | g/m² | 500 | 770 | 620 | 600 |
| Fabric caliper | mm | 0.9 | 1.3 | 1.1 | 1.85 |
| Clear mesh opening | mm | 0.53 × 0.47 | 0.72 × 0.72 | 1.09 × 1.18 | 2.50 × 2.77 |
| Air permeability | m³/(m²·h) | 10100 | 11000 | 18000 | 32000 |
| MD breaking strength | N/cm | 1600 | 1600 | 1600 | 1600 |
| CD breaking strength | N/cm | 650 | 650 | 650 | 650 |
| Ordering details | |||||
| Joint | SP – Spiral-pin joint | SP – Spiral-pin joint | SP – Spiral-pin joint | SP – Spiral-pin joint | |
| Edge finish | PU – Polyurethane edge seal | PU – Polyurethane edge seal | PU – Polyurethane edge seal | PU – Polyurethane edge seal | |
| Color | B – Blue | B – Blue | B – Blue | B – Blue | |
| Order dimensions (example) | mm | W2000-L12000 | W2000-L12000 | W2000-L12000 | W2000-L12000 |
| Order code (example) | DY-LSM-PET-01/W2000-L12000/SP/PU/B/R01 | DY-LSM-PET-02/W2000-L12000/SP/PU/B/R01 | DY-LSM-PET-03/W2000-L12000/SP/PU/B/R01 | DY-LSM-PET-04/W2000-L12000/SP/PU/B/R01 | |
| Dimensions | Custom finished dimensions to the machine drawing. | ||||
| Specification scope | Nominal fabric specifications; assembly details apply as listed. | ||||
No. Yarn diameter also determines the clear opening. State aperture in µm or mm and mesh count with its counting convention.
It is primarily an aperture-screening surface. Fine particle retention may require a different cloth or cake-filtration process.
Elongated or flexible particles may pass differently from compact particles of the same nominal size. Trial representative feed and define the required separation.
Send clear-opening requirements, target reject size, slurry flow and solids, belt dimensions, support arrangement, roller diameters and current belt sample.